Equipment Electricity Cost
Estimate electricity use from input power, equipment count and operating time. Apply your energy rate and a separately entered monthly charge.
Use equipment electricity cost →CALCULATORS BY INDUSTRY
Work through heat, airflow, efficiency and operating-energy comparisons.
20 free tools. No signup. Methods, examples and source links on every page.
Estimate electricity use from input power, equipment count and operating time. Apply your energy rate and a separately entered monthly charge.
Use equipment electricity cost →Convert a known power value between watts (W), kilowatts (kW), mechanical horsepower (hp) and Btu IT per hour. Calculating electrical power from volts and amps is a different task that may also need power factor and phase details.
Use power conversion →Convert a steady volumetric flow between liters per minute, liters per second, cubic meters per hour and U.S. gallons per minute.
Use water flow unit conversion →Turn your fuel unit price and heat content into input-energy cost, including a separate delivered-purchase perspective.
Use fuel cost per input energy →Use an entered output/input efficiency and matching fuel heat content to estimate metered fuel use and annual operating cost.
Use useful heating cost →Hold useful heat constant, apply an entered seasonal COP and boiler efficiency, then compare rounded energy and fixed operating costs.
Use heat pump vs boiler cost →Compare two output/input boiler efficiencies against the same useful-heat requirement and fuel-energy price.
Use boiler efficiency cost scenario →Convert entered useful cooling energy through a matching COP or EER convention to an electrical-energy cost.
Use cooling energy cost →Apply a supplied gas billing-volume factor and heating value, with explicit energy-unit conventions.
Use natural gas volume to energy →Convert equivalent steady-state COP, EER and electrical kW per refrigeration ton on the same rating basis.
Use cooling efficiency unit converter →Conductivity cycles = circulating conductivity ÷ makeup conductivity.
Use cooling tower concentration ratios →Accounted makeup requirement is the sum of evaporation, blowdown, drift, leakage and overflow during one common period.
Use cooling tower water balance →Let r be new speed divided by positive reference speed.
Use fan affinity law scenario →Air power in kW = actual cubic metres per second × pressure rise in Pa ÷ 1,000.
Use fan air power →Signed heat removed in kW = mass flow in kg/s × enthalpy drop in kJ/kg.
Use heat exchanger thermal duty →Counterflow terminal approaches are hot-in minus cold-out and hot-out minus cold-in.
Use heat exchanger lmtd →Effective UA in kW/K = entered thermal duty in kW ÷ (applicable correction factor × reviewed LMTD in K).
Use heat exchanger ua scenario →Coefficient of performance is useful heating or cooling output divided by electrical input on matching energy and time boundaries.
Use measured heat pump cop →For an ideal fixed-geometry centrifugal-pump similarity scenario, r = new speed / reference speed.
Use pump affinity law scenario →Area-normalized resistance in m²·K/W is the sum of each layer’s thickness in metres divided by conductivity in W/(m·K).
Use planar thermal conduction →Use the system boundary and units stated on the page.
Enter suitable measured flows, temperatures and seasonal efficiencies.
Sizing, comfort, ventilation compliance and refrigerant selection require separate review.
Start with the example, replace the assumptions with your measurements, then change one input to see its effect. Save or export the scenario if you need to keep its basis.
How Case calculators are built and checked →Read practical calculation guides or browse another industry.