Heating & operating scenarios
Heat Pump vs Boiler Cost Calculator
Hold useful heat constant, apply an entered seasonal COP and boiler efficiency, then compare rounded energy and fixed operating costs.
Your numbers.
A clearer decision.
Inputs stay in this browser.
INPUT GROUP 01
Same useful heat over one period
INPUT GROUP 02
Rates and period fixed costs
Check the assumptions before acting on a result.
Read the method and exampleYOUR CALCULATION
The heat-pump scenario has the lower modeled rounded operating cost.
Boiler fuel input energy · kWh
Heat-pump operating cost
Boiler operating cost
Boiler cost minus heat-pump cost
Illustrative inputs loaded. Replace them with your own assumptions.
How the heat pump vs boiler cost calculator works
Heat-pump electric input = useful heat ÷ seasonal COP. Boiler fuel input = the same useful heat ÷ boiler efficiency fraction. Both denominators must be positive. Seasonal COP is an output/input energy ratio in matching units, not a percentage or a single-condition rating assumed valid for every season.
Each scenario extends unrounded input energy at its entered energy rate and rounds that charge half-up to cents. Add its separately rounded fixed operating cost. Heat-pump saving is rounded boiler cost minus rounded heat-pump cost; negative saving favors the boiler scenario. The winner uses those displayed rounded totals.
Fixed costs remain at zero heat demand. This does not size equipment, estimate a building heating load, guarantee comfort or forecast seasonal performance. Backup heat, defrost, auxiliary electricity, distribution losses and demand charges must be included in compatible performance/rate inputs or addressed separately. Capital costs, rebates, finance and emissions are excluded. DOE defines COP and annual fuel utilization efficiency; no purchasing standard is applied by this comparison.
Worked example
20,000 kWh useful heat at seasonal COP 3 requires about 6,666.667 kWh electricity. At 0.20/kWh plus 200 fixed cost, the heat-pump scenario costs 1,533.33. At 90% boiler efficiency, fuel input is about 22,222.222 kWh; at 0.08/kWh plus 150 fixed cost, it costs 1,927.78. The heat-pump scenario is 394.45 lower. COP 2 instead makes it 2,200, which is 272.22 higher than the boiler.
Sources and assumptions
The source material explains the underlying calculation or pricing structure. Entered prices, costs, schedules and scenario choices are your assumptions; this tool does not obtain supplier quotes or predict actual results.